Welcome to Cerra Metal Works
Horizontal/vertical control gap tie for brick and block work. This tie will retain masonry integrity against lateral wind loads, and sleeves – back plate will absorb differential movement.
Conforms to corrosion resistance set by AS/NZS 2699.2:2020 / AS 3700.
| AS/NZS 2669.1:2020 | CGT 3 (40mm Gap) Mean (range) |
|---|---|
| Preliminary Stiffness (kN/mm) | 0.79 (0.44 – 1.29) |
| Serviceability Stiffness (kN/mm) | 1.29 (0.91 – 1.53) |
| Peak Load (kN) | |
| Mean Load | 3.02 (2.38 – 3.75) |
| Characteristic Strength | 2.08 |
When ordering please supply us with the part number and quantity you require