Ensure the longevity of your masonry with this sliding tie. It establishes a crucial vertical control gap, enabling vertical expansion up to 40mm in brick and block walls. also allowing in-plane movement. This tie doesn't just allow for movement; it also secures masonry against lateral wind loads and features a de-bonding slide that effectively manages and absorbs differential movement, preventing internal stresses.
Conforms to corrosion resistance set by AS/NZS 2699.2:2020 / AS 3700.
| AS/NZS 2669.1:2020 | CGT 1B (40mm Gap) Mean (range) |
|---|---|
| Preliminary Stiffness (kN/mm) | 0.58 (0.40 – 0.74) |
| Serviceability Stiffness (kN/mm) | 1.07 (0.76 – 1.39) |
| Peak Load (kN) | |
| Mean Load | 1.81 (1.66 – 2.04) |
| Characteristic Strength | 1.49 |
| AS/NZS 2669.1:2020 | CGT 1B (40mm Cavity) Mean (range) |
|---|---|
| Preliminary Stiffness (kN/mm) | 0.16 (0.11 – 0.29) |
| Serviceability Stiffness (kN/mm) | 0.32 (0.25 – 0.41) |
| Peak Load (kN) | |
| Mean Load | 3.18 (2.83 – 3.70) |
| Characteristic Strength | 2.53 |
When ordering please supply us with the part number and quantity you require